banner

Products

Gw9

Gw9

Isolator switch A switching device, mainly used for "isolation power, switching operation, to connect and cut off the sm
SHARE

Description

Basic Info.
Model NO. GW9-12G/630A
Number of Poles Unipolar
Grounding Single Ground
Series Single-Stage
Run Turn the Horizontal
Switching Mode Single Throw-in
Common Model RW5
Structure of Operating Manual
Certification ISO, CE, ISO9001
Brand People
Rated Voltage 12kv
Transport Package Export Standard
Specification standard
Trademark PEOPLE
Origin China
HS Code 85351000
Production Capacity 1000000
Product Description

Gw9-12g/630A 12kv Single Phase Disconnector Isolator Switch Disconnecting Switch Ds


Gw9-12g/630A 12kv Single Phase Disconnector Isolator Switch Disconnecting Switch Ds


Gw9-12g/630A 12kv Single Phase Disconnector Isolator Switch Disconnecting Switch Ds


Gw9-12g/630A 12kv Single Phase Disconnector Isolator Switch Disconnecting Switch Ds


Isolator switch
A switching device, mainly used for "isolation power, switching operation, to connect and cut off the small current circuit", no arc function.
Isolation switch, that is, in the sub-position, the contact between the requirements of the insulation distance and clear off the mark; in the joint position, can carry the normal circuit conditions and the current conditions within the specified conditions Such as a short circuit). (IEV441-14-05)
Disconnector (commonly known as "knife gate"), generally refers to the high-voltage isolation switch, that is, rated voltage above 1kV isolation switch, usually referred to as the isolation switch, is the most used in high-voltage switch electrical appliances, its own work Principle and structure is relatively simple, but due to the use of large, high reliability requirements, the substation, power plant design, establishment and safe operation are greater impact. Is the main feature of the disconnector is no arc suppression capability, only in the absence of load current in the case of sub-combined circuit. Disconnector is used for all levels of voltage, used to change the circuit connection or the line or equipment and power supply isolation, it is no drying capacity, can only use other equipment to disconnect the line after the operation. In general, interlocks are provided with an erroneous operation to prevent the switch from being overloaded, and pins are sometimes required to prevent the switch from breaking off under large magnetic forces
Product Description

Outdoor AC Gang isolator switch 11kv/400A-33kv/600A used in 3phase AC 50/60Hz power circuit, it is used as switching on and switching off at the voltage with no load. It apply to IEC standard. IEC60964: 1996, IEC62271-102: 2002
Note: For detail, please refer to the catalogue



Gw9-12g/630A 12kv Single Phase Disconnector Isolator Switch Disconnecting Switch Ds









Contact Us:
Contact Person: Ms. Rachel
Office Address: No. 555, Chezhan Road, Liushi, Yueqing city, Zhejiang,China
Factory Address: No111, Xiaolan Industrial zone, Nanchang, Jiangxi, China
Post Code:325604

Our Contact