banner

Products

VS1 12kv Indoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report

VS1 12kv Indoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report

VS1 12kv Indoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report General Description ZN63A(VS1)-12 serie
SHARE

Description

Basic Info.
Model NO. VS1-12/1250-31.5
Poles Number 3
Type Circuit Breaker
Function Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification VDE, ISO9001-2000, CE, CCC
Short Circuit Breaking Current 20kA,25kA,31.5kA,40kA
Assembly Type Common Insulated Cylinder
Operation Type Fixed & Withdrawable
Phases Distance 150mm/210mm/275mm
Mechanical Edurance 30000 Cycles
Rated Frequency 50Hz
Rated Voltage 12/24kv
Rated Current 630A, 1250A, 1600A,2000A, 2500A, 3150A, 4000A
Transport Package Non-Solid Wooden Case
Specification IEC: M2-E2-C2
Trademark Longxiang Electrical
Origin Baoji, Shaanxi China
HS Code 85389000
Production Capacity 16000 Sets / Year
Product Description
VS1 12kv Indoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report
General Description
ZN63A(VS1)-12 series of indoor vacuum circuit breaker is used for indoor 12kv switchgear, it is suitable to control and protect transmission and distribution system such as electric network equipment and industrial & minning industry etc as their protection and control unit.It can match with KYN28(GZS1), XGN and GG1-A series of switchgears.The products meet standards of GB1984-2003.This series of products include:VCB truck, isolation truck and fuse truck etc.1.This series of VCB is used integrated design for operating mechanism and VCB body with reasonable,beautiful and compact arrangement.2.This series of VCB adopted vertical insulation house against impact due to different weather,it can effectively prevent VIS against damage by exterior factors.3.With two kinds of installation unit:fixed type and withdrawable type,it can meet different assembling requirements between switchgear and breaker.
Applying ambient conditions
1.Ambient temperature:-10ºC~+40ºC.2.The height above sea level:≤1000m(besides the special requirements).3.Relative humidity:the average humidity of a day should be no more than 95%;the average humidity of a month should be no more than 90%.4.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa;the average pressure of a month should be no more than 1.8kPa.5.Earthquake intensity:not exceed 8 degrees.6.It should be installed in the places without fire, explosion, serious filth, chemical erosion and violent vibration.

VS1 12kv Indoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report


Our Factory

VS1 12kv Indoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report


Packaging & Delivery

VS1 12kv Indoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report

VS1 12kv Indoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report

Welcome for enquiry and factory visit!

Our Contact