banner

Products

Easy Assembled Substation Double Ground Medium Voltage Switch Disconnector

Easy Assembled Substation Double Ground Medium Voltage Switch Disconnector

Substation double ground mv switch disconnector 1.Simple Structure, reliable property, wide usage, economical and long-t
SHARE

Description

Basic Info.
Model NO. GW4
Number of Poles Three Pole
Grounding Double Ground
Series Three
Run Turn the Horizontal
Common Model Gw
Structure of Operating Manual
Certification Veiki
Brand Yongde
Application Substation
Transport Package by Wood Carton
Specification IEC62271-102: 2005 and IEEE Std C37.30-1997
Trademark YONGDE
Origin China
HS Code 8535300000
Production Capacity 2000 Sets/Month
Product Description
Substation double ground mv switch disconnector
1.Simple Structure, reliable property, wide usage, economical and long-time life.
2.Complete specification and satisfy user's different parameters requirements.
3.Connecting terminal and the electric pole is made by casting aluminum-alloy and section bar, having the good property of high-intensity, good flowing and anti-corrosion
4.In the galvanic circle, the section is the combination structure made by screw fix linking, having the good property of stable flowing, high reliability, simple change way and convenient adding volume way.
5.In the galvanic circle, the contact and finger is made by T2Y pure copper tap whose connecting part is coated by 30μ M silver.
6.Finger spring is made by the stainless steel and its design is the inside hiding and outside press structure which is convenient for testing and changing.
7.Bearing block is made by high-intensity casting steel (disposed by hot zinc coating), the height can be adjusted and have the function of damping.
8.All the operating rod and linking rod are supplied by manufacturer, which is convenient for loading, adjusting and testing.
9.Can be supplied as a whole above the ground according to user's requirement.
NoItemTechnical parameter
1Rated Voltage kV72.5123145245
2Rated Current A1250 1600 2000 2500 3150 4000
3Rated Short Time withstand current and Time kA/s25~50/4
4Rated Peak withstand current kA63~125
51min power frequency withstand voltage (effective value) kVTo earth140230275460
To phase140230275460
Across Isolating DS180300315605
6Lightning Impulse wishstand voltage
(peak value) kV
To earth3255506501050
To phase3255506501050
Across Isolating DS4056507501200
7Rated mechanical terminal load NLevel of lateral load750150015002000
Level of vertical load500100010001500
Vertical750100010001250
8
9Max Man Operative Moment N.M200
10Motor Drive operating mechanism control voltage VAC220;DC110, 220
11Motor Drive operating mechanism motor voltage VAC220, 380;DC110, 220

Drawing:

Easy Assembled Substation Double Ground Medium Voltage Switch Disconnector